ImagePro>Circular AOI


[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

ImagePro>Circular AOI



I do not know whether Manual Tag analysis utilizes circular AOIs. However, trying to overcome the problems of Tags with a set of circular AOIs, I found the same kinds of problems: circular AOIs give incorrect (unexplainable) averaging with 12 and 16 bit images, independently from the pixel sampled and in absence of intensity calibrations; in addition there is an imperfect  matching between the circular AOI boundaries and the pixels sampled.
If I insist on this problem is not to criticize IPP, with I consider a powerful, versatile and invaluable program, but solely to signal a bug.
Giacomo Diaz

--------------------------------
Prof. Giacomo Diaz Dept. Cytomorphology University of Cagliari Cittadella Universitaria Monserrato 09042 Monserrato (CA) ITALY E-mail: gdiaz@unica.it Fax +39.070.675.4003 Tel +39.070.675.4081, 070.675.4046